Testing instruments

From uncured compound to finished part, every measurement covered

Rheology with Prescott Instruments, automated mechanical testing with LabsCubed: two manufacturers who design and build their instruments in-house.

The lab testing chain

What each instrument measures

01Uncured compoundViscosity, scorchMooney · Mini-Mooney
02CuringCure curveMDR · ODR · Mini-MDR
03Dynamic behaviourModulus, dampingRPA · DMA
04Mechanical propertiesTensile, tearLabsCubed · ISO 37 · ASTM D412
05PlasticsTensile, flexureLabsCubed · ISO 527 · ASTM D638
United Kingdom · since 1994
Prescott Instruments

Rubber and plastics testing instruments, designed, built and supported in-house in the UK. More than 500 customers worldwide.

  • MDR, ODR and RPA rheometers
  • Mooney and Mini-Mooney viscometers, Mini-MDR
  • DMA, melt flow rate (MFR), volumetric sample cutters
  • Automatic sample changers
  • ISO 17025 accredited calibration and MDR 2000 / MV 2000 Alpha retrofit
Canada New
LabsCubed

Automated testers for polymer labs with medium to high volumes: the operator loads specimens, starts the run and moves on.

  • Elastomer tensile and tear (ISO 37, ASTM D412, ASTM D624)
  • Plastics tensile and flexure (ISO 527, ASTM D638, ISO 178, ASTM D790)
  • Robotic loading of several specimens per run
  • Centralised data that connects to your lab software
United Kingdom · online shop
Rheometer Spares

Prescott Instruments’ online shop: spare parts, consumables and tools for rubber testing instruments. Order directly, with worldwide delivery.

  • Dies and rotors for MDR and ODR rheometers and Mooney viscometers
  • Seals, torque transducers and temperature probes
  • Testing consumables and volumetric sample cutting
  • Parts compatible with most major manufacturers
  • Labline licence renewals, available exclusively online

Shop online →

FAQ

Frequently asked questions

What is the difference between a Mooney viscometer and an MDR?

The Mooney measures viscosity and scorch time of the uncured compound. The MDR follows vulcanisation and plots the cure curve. Both are complementary in quality control.

MDR or ODR?

The MDR (rotorless chamber) gives better temperature control and faster tests. The ODR (oscillating disc) remains in use for continuity with older specifications.

Why automate tensile testing?

To free technician time, run tests unattended and reduce operator-related variability.

My MDR 2000 is old. Should I replace it?

Not necessarily. The Prescott retrofit modernises the electronics and software of MDR 2000 and MV 2000 Alpha units while keeping the mechanics.

Can I see a demo?

Yes, on request, remotely or on site depending on the instrument.

A process to improve, a trial to run?

Our technical team replies within one working day.

Talk to an expert